Automatic Concrete Cylinder Tester for ASTM C39 Strength Reports

  | Share on Twitter Twitter | Submit to Digg digg it |  Add to delicious  delicious |  Submit to StumbleUpon StumbleUpon |  Share on LinkedIn LinkedIn | Submit to Reddit reddit 

All concrete testing laboratories produce essentially the same compressive strength test reports. So, how can a laboratory manager create a distinctive product while boosting profitability?

Speed Control
Concrete exhibits loading-rate sensitivity relative to compressive strength,1,2 so ASTM C39, "Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens,"3 limits loading rate to 0.2 to 0.3MPa/sec (28 to 42 psi/sec). This helps ensure consistency within and among laboratories.

Almost 70% of the testing machines now in service are manually operated. The operator is therefore required to manually adjust a valve to achieve a loading rate within specification. Unfortunately, these adjustments can be inaccurate, particularly because only about half of the concrete testing machines now in service have any provision to indicate load rate. A fifth of testing machines now in service do have digital indicators that provide loading rates, but the attained rates aren't verifiable after the tests.

ADMET Auto Concrete Tester

Figure 1 - ADMET MegaForce II Automatic Concrete Testing System.

A Step in the Right Direction
To address the shortcoming of nonverifiable loading rates, manually operated machines are now being offered that calculate and report the average loading rate according to ASTM C39 requirements and can generate load and stress versus time curves to verify that a test was performed according to specification. They also offer digital indicators that provide a live indication of loading rate. These systems don't, however, eliminate the possibility that an operator could perform tests at rates exceeding ASTM C39 limits.

More Control
There is clearly a need for an automatic concrete testing system that can control loading rate. Control systems used on conventional universal testing machines, however, aren't appropriate for concrete testing applications. Most concrete testing machines in operation are hydraulically actuated and operate at oil pressures as high as 68.9 MPa (10,000 psi). In contrast, conventional servo-hydraulic testing systems operate at maximum pressures of about 31 MPa (4500 psi). These systems therefore have large-and very expensive-actuators, and their high cost precludes them from widespread use in concrete testing.
Over the past six years, ADMET, Inc. has offered a low-cost, reliable, automatic concrete testing system that addresses these issues. As shown in Fig. 1, the MegaForce II automatic testing system works with compression machines that operate to 68.9 MPa (10,000 psi), prevents the operator from overriding the testing process, and provides verification of loading rates-all for 50 to 75% less cost than for a comparable servo-controlled testing machine. The automatic testing system can be installed on new machines or retrofitted to existing machines, generating further cost savings.

References
1. Carino, N.J.; Guthrie, W.F.; Lagergren, E.S.; and Mullings, G.M. "Effects of Testing Variables on the Strength of High-Strength (90 MPa) Concrete Cylinders," High-Performance Concrete: Proceedings, ACI International Conference, Singapore, 1994 (SP-149), V.M. Malhotra, ed., American Concrete Institute, Farmington Hills, MI, 1994, pp. 589-632.
2. Han, N., and Walraven, J.C., "Properties of High-Strength Concrete Subjected to Uniaxial Loading," High-Performance Concrete: Proceedings, ACI International Conference, Singapore, 1994 (SP-149), V.M. Malhotra, ed., American Concrete Institute, Farmington Hills, MI, 1994, pp. 269-288.
3. ASTM C39/C39M-05e1, "Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens," ASTM International, West Conshohocken, PA, 2005, 7 pp.

Click here for more information on ADMET's concrete testing systems.


ASTM C1609 Flexural Testing of Fiber-Reinforced Concrete Beams

  | Share on Twitter Twitter | Submit to Digg digg it |  Add to delicious  delicious |  Submit to StumbleUpon StumbleUpon |  Share on LinkedIn LinkedIn | Submit to Reddit reddit 

Fiber reinforced concrete (FRC) is finding increased use in construction. FRC offers several advantages over rebar or wire mesh reinforced concrete including increased crack resistance, ductility, energy absorption, impact resistance and residual strength. FRC can also significantly lower materials and labor costs compared to rebar or wire mesh reinforced concrete.

ASTM C1609, Standard Test Method for Flexural Performance of Fiber-Reinforced Concrete (Using Beam With Third-Point Loading),   is one specification governing the testing of Fiber Reinforced Concrete Beams.

C1609 requires the use of a closed-loop, servo controlled compression testing machine. The test is run at specified net deflection rates as measured at the mid-span point of the beam.

The testing machine must be capable of controlling at very slow speeds. Electromechanical testing machines are best suited for this type of application.  

Figure 1 shows a typical test setup to perform the C1609 test. It is a third-point loading fixture with two support points and two loading noses on the top of the beam. A rectangular jig surrounds the beam and is mounted on the beam's neutral axis directly over the supports. Two displacement transducers, one on each side of the beam, are mounted mid-span to measure beam deflection. The output of each transducer is averaged together to provide the net deflection measurement. This configuration ensures accurate measurement of mid-span deflection and minimizes errors due to concrete specimen twisting or seating in the supports.

 

 

 Figure 1. Typical ASTM C1609 Test Fixture.

The test is run at a specified net deflection rate to a net deflection of L/600 (where L is the support span distance). After which it can be run at a higher specified net deflection rate until the specified endpoint.

Table 1. ASTM C1609 Net Deflection Testing Rates.  

ASTM C1609 data analyses include 1st Peak Strength, Ultimate Strength, Residual Strength at L/600, Residual Strength at L/150 and Toughness, which is the area under load versus net deflection curve from 0 to L/150.

 

 

 Figure 2 - Stress versus net deflection curve with ASTM C1609 analysis results.

 

Click here for more information on ADMET's concrete testing systems. 

 

 


Testing Equipment Required for ASTM D3574 Urethane Foam

  | Share on Twitter Twitter | Submit to Digg digg it |  Add to delicious  delicious |  Submit to StumbleUpon StumbleUpon |  Share on LinkedIn LinkedIn | Submit to Reddit reddit 

ASTM D3574 (D 3574) applies to slab, bonded, and molded flexible cellular urethane foams.  There are many tests in this specification including tests for density, ball rebound, airflow, etc.  However, the most common tests in the specification are these mechanical tests:

1. Test B1 - Indentation Force Deflection Test (IFD) - Specified Deflection

2. Test B2 - Indentation Force Deflection Test (IFD) - Specified Force

3. Test C - Compression Force Deflection (CFD)

4. Test E - Tension Test

5. Test F - Tear Resistance Test

All of these tests are performed on a universal testing machine, often times referred to as a tensile testing machine.  The machine control software must be capable of segmented machine control testing profiles.  Not all testing machines will perform these tests correctly; All ADMET testing machines equipped with MTESTQuattro software are capable of these tests.

Other equipment needed to perform the tests described above are:

Tests B1, B2, C 

1. Circular 8" compression platen with a swivel joint

2. Square 16" x 16" (min.) compression platen with 6.5mm holes on 20mm centers

Tests E, F 

 1. Manual or pneumatic vise grips with serrated inserts

That is the end of the equipment requirements.

The videos below show Foam IFD, Tear, and Tensile Tests.  Use the links above each video to read more about each test.

Indentation Force Deflection Test 

  

 

Foam Tensile Strength Test

 

Foam Tear Resistance Test

 

Click here if you would like to ask an engineer a question, or click here if you would like a quote on a system.


Plastic Bucket Compression Test

  | Share on Twitter Twitter | Submit to Digg digg it |  Add to delicious  delicious |  Submit to StumbleUpon StumbleUpon |  Share on LinkedIn LinkedIn | Submit to Reddit reddit 

We recently performed a compression test on a 3.5 gallon HDPE plastic bucket. The purpose of the test was to measure the force required to secure the lid onto the bucket and the force required to make the bucket/lid assembly collapse. These are important characteristics to understand to improve the lid sealing operation and shipping characteristics of the container. Our eXpert 2613 dual column universal testing machine was programmed to compress the bucket at a constant 1" per minute.  The chart generated from the MTESTQuattro testing software will allow us to find the peak closure force, and the peak force before the bucket collapsed.  We were surprised that the bucket withstood nearly 3500 pounds of force before it buckled. You can see a video of the test below.

 

 For more information on this system, please visit our plastics page.


All Posts